Hygienic.Adiabatic.Exact.

The F1C combines pressurised water atomization with a secondary evaporation stage to humidify and adiabatically cool commercial air. Conductivity, temperature, pressure, and sequential hygiene flushes keep the water process under control.

  1. 01Demand
  2. 02Atomization
  3. 03Evaporation
  4. 04Humidity

Humidity, with the water path in view.

Most humidifiers ask you to trust a sealed circuit. F1C makes the sequence visible: water is pressurised, divided into fine droplets, evaporated through the moving air, and returned to a controlled circuit. The result is capacity that can be tuned without losing the logic of the system.

01

Atomize

Pressurised water is divided across configurable stages and introduced into the airstream as a fine mist.

02

Evaporate

Moving air and the secondary evaporation stage complete the transition from droplet to water vapour.

03

Protect

Water quality, pressure, temperature, and configured flush sequences keep the circuit supervised.

F1C / Water circuit

Hygiene belongs inside the operating cycle.

F1C treats water care as part of humidification, not as a disconnected service task. The controller measures the conditions that change the water circuit and gives normal humidity demand priority over maintenance routines.

Water quality

Temperature-compensated conductivity and water temperature remain visible to the control system.

Pressure supervision

Inlet and pump-side pressure provide the basis for dry-run and stability alarms.

Sequential flush

Enabled stages are flushed in order, including the dedicated drain path.

Circuit protection

Leak, motor-temperature, board-temperature, and water-temperature conditions remain supervised.

One system. Four ways in.

The same product story serves every discipline. Each role finds the detail it needs without moving through a separate miniature website.

Specify

Review the process, interfaces, water requirements, and technical resource subjects.

Install

Find installation guidance, commissioning information, and a direct technical contact.

Operate

Understand normal states, hygiene routines, alarms, and maintenance responsibilities.

Integrate

Connect the humidifier through analog demand, Modbus, BACnet, Ethernet, or service access.

Control that stays legible.

The controller combines local machine protection with the interfaces expected by modern buildings. Technicians can use service access; building systems can use the fieldbus; operators can see a clear status without being exposed to internal implementation detail.

Analog

Demand input

0–10 V and 4–20 mA support the primary building-system signals.

Network

Open networks

Modbus RTU/TCP and BACnet/IP or MS/TP keep supervisory workflows available.

Service

Service access

Ethernet web access supports setup and maintenance.

Made for rooms where humidity has to be right.

Use F1C where comfort, hygiene, and building control must work together—from commercial premises to sensitive technical environments.

  • Commercial HVAC
  • Healthcare and laboratories
  • Data centres
  • Hospitality and residential

Start with the system. Refine with the specialists.

Explore the F1C platform, follow the hybrid process, or send a project enquiry to the team that can connect requirements to the right technical answer.